SCIEX 5500 Low Sensitivity Repair and Agilent HPLC System Recovery

We were called for SCIEX 5500 low sensitivity repair on an LC-MS system paired with an Agilent HPLC. The mass spectrometer was not delivering proper sensitivity, and the connected HPLC stack also needed testing and follow-up service to keep the full system operating correctly. Diagnostics showed contamination in the front end of the mass spectrometer, affecting the ion source area and related front-end components. We cleaned the affected MS components, restored proper response, and completed tun...
Read More

Agilent 1100 Pressure Problem Repair

Agilent 1100 pressure problem repair was needed for a system that would not build pressure during startup after installation and connection. The HPLC repeatedly failed the pressure test even though the leak test passed, which prevented the system from moving into normal operation. Our diagnostics included connection review, firmware updates, pump service, and testing of the related support equipment. The pump seals and pump head components were serviced first, but the pressure problem remained....
Read More

Agilent 6890 GC Autosampler Carousel Failure Diagnosed

An Agilent 6890 GC autosampler Z-axis homing error can come from more than one part of the autosampler system. In this case, the customer’s autosampler was not functioning and injections could not be performed, even after a replacement injection tower had already been installed. Our evaluation focused on the remaining autosampler components. During inspection of the carousel tray assembly, we found that the drive belt was torn and no longer able to transmit motion. The belt was replaced using...
Read More

Agilent Microarray Scanner Autofocus Error Repair

We serviced two Agilent G2565CA microarray scanners after the customer reported an Agilent microarray scanner autofocus error during slide scanning, along with intermittent color distortion, focus instability, and image discoloration on one of the units. During diagnostics, the affected scanner initially passed routine preventive maintenance checks, but the fault appeared later in operation. We first replaced the autofocus coil cable, but the issue continued after several hours of use. Further s...
Read More

Resolving a PerkinElmer EnVision Software Issue

This PerkinElmer EnVision software issue appeared after the system workstation was removed from a previous domain environment. The customer needed the instrument restored for standalone operation, but the existing computer setup was preventing the EnVision software from functioning correctly and blocking normal communication with the instrument. Our diagnostics showed that the problem was caused by leftover domain-related and Windows configuration settings from the previous installation. A softw...
Read More

Pre-Purchase HPLC System Diagnostics — Catching Problems Before the Purchase

Investing in a used HPLC system can be a smart decision — but only if you know exactly what you’re getting. At ScientifiCo, we offer detailed HPLC System Diagnostics for laboratories looking to buy second-hand or refurbished analytical equipment. Here’s a real example where our assessment helped prevent a potentially costly mistake. Equipment Inspected This system consisted of the following components: Description Model Pump QSM Autosampler SM FTN Column Manager CM Detector PDA Our cli...
Read More